SELF CONTAINED SYSTEMS

Optimum Series

  • Advanced blower fans.
  • Quiet operation.
  • UV-C Lighting System (Optional Add-on)
  • Condensate evaporator.
  • TXV expansion valve.
  • Liquid-temperature-measuring Bottle Probe.
  • Coated evaporator coil.
  • Front or rear power.
  • Single piece mounting bracket.

The Optimum Series systems incorporate the latest and greatest features in wine cooling into their design, at an affordable price. Advanced blower fans replace axial fans, which accelerates the ow of cold air in your cellar at an even distribution. A condensate evaporator has been added to effectively manage condensate produced by the coil (up to 3 ounces of condensate per hour). The unit also utilizes a smart-metering TXV valve that efficiently manages the ow of refrigeration through the system to ensure optimal performance. In order to keep your cellar at 55°F, the condenser intake should not exceed 85°F. This makes interior installation ideal for Optimum Series units. Our Ultimate Series units are better suited for exterior installations.

Model

2200

3300

4400

8800

Cellar Size 300 650 1000 1500
BTUh (w/85°F air entering the condenser coil) 1453 2049 2253 4241
Dimensions 17.5”L x 14.25”W x 15.75”H 16.25”W x 22”H x 22.25”D
Refrigerant R-134a R-134a R-134a R-134a
HP 1/8 1/6 1/6+ 1/2
Voltage Rating 115V (15 amp dedicated circuit required) 115V (20 amp dedicated circuit required)
Weight (lbs) 65 104
AMPS 3.2 (running amps) 3.7 (running amps) 4.7 (running amps) 10.9 (running amps)
Drainline 1/2” ID clear plastic tubing
Installation Through-the-Wall, Partially Ducted
Thermostat Advanced digital display, liquid-temperature-measuring bottle probe (retractable cable)
Temp. Delta Can maintain a 55°F cellar temperature with up to 85°F condenser air intake temperature
Ducting Options Exhaust air can be ducted using the optional ducting kit

CX Series

  • Direct replacement for Breezaire and Wine Mate.
  • Dynamic Air Flow design.
  • 30 degree temperature differential.
  • Flexible mounting bracket.
  • Advanced Digital Controller.

The CX Standard –Thru-Wall System has a dynamic air flow allowing for excellent circulation of air throughout the cellar,“best-in-class” 30 degree temperature variance, and the digital controller with system safety management and anti-frost features. Furthermore, these units are a direct replacement for the Breezaire and Wine Mate Thru-Wall units.

Model
CX2200/CX2200-RPC
CX3300/CX3300-RPC
CX4400/CX4400-RPC
CX8800 (PHASED OUT)
Cellar Size 300 650 1000 2000
BTUh (w/85°F air entering the condenser coil) 1453 2049 2962 4754
CFM 118 126 216 216
Dimensions 14.25”W x 13.25”H x 16.38”D 14.25”W x 19.75”H x 21.63”D 16.25”W x 22”H x 22.25”D
Refrigerant R-134a R-134a R-134a R-134a
HP 0.57 0.8 1.16 1.86
Voltage Rating (20 amp dedicated circuit required) 115V; 230V (subject to availablility)
Weight (lbs) 65 66 67 74
AMPS 4.5 (running amps) 4.9 (running amps) 9 (running amps) 10 (running amps)
dBA (Evaporator/Condenser) 63 / 63 63 / 64 63 / 64 68 / 68
Drainline 3/8” Condensate (rear location only)
Installation Through-the-Wall, Partially Ducted
Thermostat Advanced electronic control system
Temp. Delta Can maintain a 55°F cellar temperature with up to 85°F condenser air intake temperature

Ultimate Series

  • Variable speed fans.
  • Operates in extreme environments.
  • 55 degree temperature differential.
  • Flexible mounting bracket.
  • Control mounted on front of unit or remote.
  • Ductable Exterior Exhaust
  • UV-C Lighting System (Optional Add-on)

The Ultimate – Thru Wall System is designed for installation in hotter locations or climates with a full 55 degrees temperature variance. These units can mount thru-the-wall like the CX Self Contained units or can be remote mounted outside the cellar with duct runs up to 25 ft away.

Download Product Sheet
Download Manual

Units purchased after 12/17/22

Download Manual

Units purchased before 12/17/22

Download Remote Manual

Units purchased after 12/17/22

Download Remote (24V) Manual

Units purchased after 12/17/22

Download Remote Manual

Units purchased before 12/17/22

Download Remote (24V) Manual

Units purchased before 12/17/22

Download Manual

Units purchased after 8/14/23

Download Remote Manual

Units purchased after 8/14/23

Download Remote (24V) Manual

Units purchased after 8/14/23

Model
Ultimate 3300/Ultimate 3300-R
Ultimate 4400/ Ultimate 4400-R
Ultimate 8800/ Ultimate 8800-R
Cellar Size 800 1250 2000
BTUh (w/85°F air entering the condenser coil) 3175 4126 6131
CFM 256 256 283
Dimensions 28”L x 14.25”W x 15.75”H 28”L x 14.25”W x 22.5”H
Refrigerant R-134a R-134a R-134a
HP 1/4 1/3 1/3+
Voltage Rating (20 amp dedicated circuit required) 115V (20 amp dedicated circuit required); 230V (subject to availability) 115V (20 amp dedicated circuit required); 230V (subject to availability) 115V (20 amp dedicated circuit required); 230V (subject to availability)
Weight (lbs) 150 150 170
Amps 9 (running amps) 9 (running amps) 9 (running amps)
dBA (Low/Medium/High) 51 / 58 / 66 51 / 58 / 66 57 / 59 / 61
Drainline 1/2” ID clear plastic tubing (not provided)
Installation Through-the-Wall, partially ducted, fully ducted
Thermostat Advanced digital controller, liquid-temperature-measuring bottle probe (retractable cable)
Temp. Delta Can maintain a 55°F cellar temperature with up to 110°F condenser air intake temperature
Outside Venting Can be done if the outside temperature does not exceed 110°F, the external grille cover is highly recommended.
Ducting Opetions Condensing side can be ducted.

Fully Ducted Ultimate Series

  • Entire unit mounts up to 25ft away.
  • Virtually silent operation.
  • Operates in extreme environments.
  • 55 degree temperature differential.
  • Remote Advanced Electronic Controller w/50ft cable.
  • Includes duct plenums on exhaust and supply sides.
  • UV-C Lighting System (Optional Add-on)

The Ultimate Fully Ducted are designed for installation in hotter locations or climates with a full 55 degrees temperature variance. These units are remote mounted outside the cellar with duct runs up to 25 ft away.

Download Remote Manual

Units purchased after 12/17/22

Download Manual

Units purchased before 12/17/22

Download Remote (24V) Manual

Units purchased after 12/17/22

Download Remote Manual

Units purchased before 12/17/22

Download Remote Manual

Units purchased after 8/14/23

Download Remote (24V) Manual

Units purchased after 8/14/23

Model
Ultimate-FD3300
Ultimate-FD4400
Ultimate-FD8800
Cellar Size 800 1250 2000
BTUh(w/85°F air entering the condenser coil) 2688 3794 5760
CFM 256 256 333
Dimensions 39.5″L x 14.25″W x 22.5″H (with duct plenums) 39.5″L x 14.25″W x 26″H
(with duct plenums)
Refrigerant R-134a R-134a R-134a
HP 1/4 1/3 1/3+
Voltage Rating 115V (20 amp dedicated circuit required); 230V (subject to availability) 115V (20 amp dedicated circuit required); 230V (subject to availability) 115V (20 amp dedicated circuit required); 230V (subject to availability)
Weight (lbs) 150 150 187
Amps 9 (running amps) 9 (running amps) 10 (running amps)
Duct Size 8” Supply • 8” Return(evaporator and condenser) 8” Supply • 10” Return
(evaporator and condenser)
Drainline 1/2” ID clear plastic tubing (not provided)
Installation Can be installed up to 25 duct feet away from cellar.
Thermostat Advanced digital display (50ft. cable), liquid-temperature-measuring bottle probe (50ft. cable)
Temp. Delta Can maintain a 55°F cellar temperature with up to 110°F condenser air intake temperature
Outside Venting Can be done if the outside temperature does not exceed 110°F, the external grille cover is highly recommended.

Ultimate PLUS Fully Ducted Series

  • UV-C Lighting System (Optional Add-on)
  • Entire unit mounts up to 25ft away.
  • Virtually silent operation.
  • Operates in extreme environments.
  • 55 degree temperature differential.
  • Remote Advanced Electronic Controller w/50ft cable.
  • Includes duct plenums on exhaust and supply sides.

The Ultimate Fully Ducted are designed for installation in hotter locations or climates with a full 55 degrees temperature variance. These units are remote mounted outside the cellar with duct runs up to 25 ft away.

Model
Ultimate PLUS-PFD3300
Ultimate PLUS-PFD4400
Ultimate PLUS-PFD8800
Cellar Size 800 1250 2000
BTUh (w/85°F air entering the condenser coil) 4060 5521 6025
CFM 326 with blowers in top orientation;
312 with blowers in side orientation
340 with blowers in top orientation;
335 with blowers in side orientation
Dimensions 37″L x 15.75″H x 15.75″W (without duct plenums); 48″L x 22.75″H x 15.75″W (duct plenums on top of unit);
15.75″H x 22.75″W (duct plenums on side of unit)
Refrigerant R-134a R-134a R-134a
HP 1/4 1/3 1/3+
Voltage Rating (20 amp dedicated circuit required) 115V (20 amp dedicated circuit required); 230V (subject to availability) 115V (20 amp dedicated circuit required); 230V (subject to availability) 115V (20 amp dedicated circuit required); 230V (subject to availability)
Weight (lbs) 115 115 115
Amps 9 (running amps) 9 (running amps) 9 (running amps)
Duct Size 8″ supply • 10″ return (evaporator and condenser)
Drainline 1/2” ID clear plastic tubing (10 feet provided)
Installation Can be installed up to 25 duct feet away from cellar.
Thermostat Advanced digital display (50ft. cable), liquid-temperature-measuring bottle probe (50ft. cable)
Temp. Delta Can maintain a 55°F cellar temperature with up to 110°F condenser air intake temperature

BTU Wizard