Duis autem vel eum iriure dolor in hendrerit in vulputate velit esse molestie consequat, vel illum dolore eu feugiat
Shop Now

Latest News

Type what you are searching for:
 

ALL COOLING SYSTEMS

OPTIMUM SERIES

  • Designed for small to medium-scale wine cellars
  • Unit power connections available from side or rear
  • 30°F temperature differential (55°F cellar with ≤ 85°F intake)
  • Digital controller conveniently located on the face of the unit
  • Liquid-temperature-measuring bottle probe for precision control
  • High-performance centrifugal fans deliver efficient, quiet cooling
  • Single-piece mounting bracket eliminates the need for a support shelf
  • Condensate management system which evaporates up to 3 oz. per hour
  • Self-contained through-the-wall design with no HVAC-R technician required
  • E-coated evaporator coil for improved performance and extended system life

Optional Accessories

  • Exhaust Ducting Kit
  • Exterior Housing
  • UV-C Lighting System

California Residents: PROPOSITION 65 WARNING

OWNER MANUALS

Owner Manual

Download Owner Manual

For previous model owner manuals, please contact us.

PRODUCT SHEETS

Part Number

U-CC2200-115-OPT-4 U-CC3300-115-OPT-4 U-CC4400-115-OPT-4 U-CC8800-115-OPT
Cellar Size 300 650 1000 1500
BTUh (w/85°F air entering the condenser coil) 1453 2049 2253 4241
Dimensions 17.5”L x 14.25”W x 15.75”H 21.64”L x 14.25”W x 22.56”H
Refrigerant R-134a R-134a R-134a R-134a
HP 1/8 1/6 1/6+ 1/2
Voltage Rating 115V (15 amp dedicated circuit required) 115V (20 amp dedicated circuit required)
Weight (lbs) 65 104
AMPS 3.2 (running amps) 3.7 (running amps) 4.7 (running amps) 10.9 (running amps)
Drainline 1/2” ID clear plastic tubing
Installation Through-the-Wall, Partially Ducted
Thermostat Advanced digital display, liquid-temperature-measuring bottle probe (retractable cable)
Temp. Delta Can maintain a 55°F cellar temperature with up to 85°F condenser air intake temperature
Ducting Options Exhaust air can be ducted using the optional ducting kit

CX SERIES

  • Designed for small to medium-scale wine cellars
  • 30°F temperature differential (55°F cellar with ≤ 85°F intake)
  • Digital controller conveniently located on the face of the unit
  • Mounting bracket designed to fit between standard wall studs
  • Dynamic airflow design for excellent circulation throughout the cellar
  • Built-in air sensor for accurate temperature and humidity monitoring
  • Direct replacement for Breezaire and Wine Mate through-the-wall units
  • Self-contained through-the-wall design with no HVAC-R technician required

California Residents: PROPOSITION 65 WARNING

OWNER MANUALS

Owner Manual

Download Owner Manual

For previous model owner manuals, please contact us.

PRODUCT SHEETS

Part Number U-CCCX2200-115-FC
U-CCCX2200-115-RC
U-CCCX3300-115-FC
U-CCCX3300-115-RC
U-CCCX4400-115-FC
U-CCCX4400-115-RC
CX8800 (PHASED OUT)
Cellar Size 300 650 1000 2000
BTUh (w/85°F air entering the condenser coil) 1453 2049 2962 4754
CFM 118 126 216 216
Dimensions 16.38”L x 14.25”W x 13.25”H 21.63”L x 14.25”W x 19.75”H 22.25”L x 16.25”W x 22”H
Refrigerant R-134a R-134a R-134a R-134a
HP 0.57 0.8 1.16 1.86
Voltage Rating (20 amp dedicated circuit required) 115V; 230V (subject to availablility)
Weight (lbs) 65 66 67 74
AMPS 4.5 (running amps) 4.9 (running amps) 9 (running amps) 10 (running amps)
dBA (Evaporator/Condenser) 63 / 63 63 / 64 63 / 64 68 / 68
Drainline 3/8” Condensate (rear location only)
Installation Through-the-Wall, Partially Ducted
Thermostat Advanced electronic control system
Temp. Delta Can maintain a 55°F cellar temperature with up to 85°F condenser air intake temperature

ULTIMATE SERIES

  • Designed for small to medium-scale wine cellars
  • Quiet operation with sound levels as low as 51 dB
  • Front display or remote KDT Plus controller (-R)
  • Ductable condenser exhaust for flexible installation
  • Variable-speed fans deliver efficient, adaptive airflow control
  • 55°F temperature differential (55°F cellar with ≤ 110°F intake)
  • Mounting bracket designed to fit between standard wall studs
  • Liquid-temperature-measuring bottle probe for precision control
  • E-coated evaporator coil for improved performance and extended system life
  • Self-contained through-the-wall design with no HVAC-R technician required

Optional Accessories

  • Exterior Grille
  • Condenser Duct Kit 
  • Evaporator Duct Kit (-R Only)
  • UV-C Lighting System
  • 24V Thermostat Conversion Kit
  • Ultimate tiR Filters (recommended replacement every 3 months)

California Residents: PROPOSITION 65 WARNING

OWNER MANUALS

PRODUCT SHEETS

Part number
U-CCUL3300ti-115-2
U-CCUL3300tiR-115-2
U-CCUL4400ti-115-2
U-CCUL4400tiR-115-2
U-CC-UL8800ti-115
U-CC-UL8800tiR-115
Cellar Size 800 1250 2000
BTUh (w/85°F air entering the condenser coil) 3175 4126 6131
CFM 256 256 283
Dimensions 28”L x 14.25”W x 15.75”H 28”L x 14.25”W x 22.5”H
Refrigerant R-134a R-134a R-134a
HP 1/4 1/3 1/3+
Voltage Rating (20 amp dedicated circuit required) 115V (20 amp dedicated circuit required); 230V (subject to availability) 115V (20 amp dedicated circuit required); 230V (subject to availability) 115V (20 amp dedicated circuit required); 230V (subject to availability)
Weight (lbs) 150 150 170
Amps 9 (running amps) 9 (running amps) 9 (running amps)
dBA (Low/Medium/High) 51 / 58 / 66 51 / 58 / 66 57 / 59 / 61
Drainline 1/2” ID clear plastic tubing (not provided)
Installation Through-the-Wall, partially ducted, fully ducted
Thermostat Advanced digital controller, liquid-temperature-measuring bottle probe (retractable cable)
Temp. Delta Can maintain a 55°F cellar temperature with up to 110°F condenser air intake temperature
Outside Venting Can be done if the outside temperature does not exceed 110°F, the external grille cover is highly recommended.
Ducting Opetions Condensing side can be ducted.

FULLY DUCTED ULTIMATE SERIES

  • Designed for small to medium-scale wine cellars
  • KDT digital controller/thermostat with 50-ft. Cable
  • Can be placed up to 25 ft. away for virtually silent operation
  • Variable-speed fans deliver efficient, adaptive airflow control
  • Liquid-temperature-measuring bottle probe for precise control
  • Dependable operation in extreme conditions with 55°F differential
  • E-coated evaporator coil for improved performance and extended system life
  • Fully ducted design keeps unit hidden and maximizes cellar aesthetics

Optional Accessories

  • Ducting Plenum
  • 24V Thermostat Conversion Kit
  • Ultimate tiR Filters (recommended replacement every 3 months)

California Residents: PROPOSITION 65 WARNING

OWNER MANUALS

Owner Manuals

Download (Remote) Owner Manual
Download Remote (24V) Manual

For previous model owner manuals, please contact us.

PRODUCT SHEETS

Part Number
U-CCUL3300FD-115-2
U-CCUL4400FD-115-2
U-CC-UL8800TIRFD-115
Cellar Size 800 1250 2000
BTUh(w/85°F air entering the condenser coil) 2688 3794 5760
CFM 256 256 333
Dimensions 39.5″L x 14.25″W x 22.5″H (with duct plenums) 39.5″L x 14.25″W x 26″H
(with duct plenums)
Refrigerant R-134a R-134a R-134a
HP 1/4 1/3 1/3+
Voltage Rating 115V (20 amp dedicated circuit required); 230V (subject to availability) 115V (20 amp dedicated circuit required); 230V (subject to availability) 115V (20 amp dedicated circuit required); 230V (subject to availability)
Weight (lbs) 150 150 187
Amps 9 (running amps) 9 (running amps) 10 (running amps)
Duct Size 8” Supply • 8” Return(evaporator and condenser) 8” Supply • 10” Return
(evaporator and condenser)
Drainline 1/2” ID clear plastic tubing (not provided)
Installation Can be installed up to 25 duct feet away from cellar.
Thermostat Advanced digital display (50ft. cable), liquid-temperature-measuring bottle probe (50ft. cable)
Temp. Delta Can maintain a 55°F cellar temperature with up to 110°F condenser air intake temperature
Outside Venting Can be done if the outside temperature does not exceed 110°F, the external grille cover is highly recommended.

ULTIMATE PLUS FULLY DUCTED SERIES

  • Designed for small to medium-scale wine cellars
  • KDT digital controller/thermostat with 50-ft. Cable
  • Supply and exhaust plenums included for easy installation
  • Can be placed up to 25 ft. away for virtually silent operation
  • Multi-directional blowers allow versatile duct configurations
  • Stainless steel drip tray for durability and easy maintenance
  • 55°F temperature differential (55°F cellar with ≤ 110°F intake)
  • Liquid-temperature-measuring bottle probe for precise control
  • E-coated evaporator coil for improved performance and extended system life
  • Fully ducted design keeps unit hidden and maximizes cellar aesthetics

Optional Accessories

  • UV-C Lighting System
  • 24V Thermostat Conversion Kit

California Residents: PROPOSITION 65 WARNING

OWNER MANUALS

Owner Manuals

Download Owner Manual
Download (24V) Owner Manual

For previous model owner manuals, please contact us.

PRODUCT SHEETS

Part Number
U-CCUL3300-115-PF-3
U-CCUL4400-115-PFD2
U-CCUL8800-115-PFD2
Cellar Size 800 1250 2000
BTUh (w/85°F air entering the condenser coil) 4060 5521 6025
CFM 326 with blowers in top orientation;
312 with blowers in side orientation
340 with blowers in top orientation;
335 with blowers in side orientation
Dimensions 37″L x 15.75″H x 15.75″W (without duct plenums); 48″L x 22.75″H x 15.75″W (duct plenums on top of unit);
15.75″H x 22.75″W (duct plenums on side of unit)
Refrigerant R-134a R-134a R-134a
HP 1/4 1/3 1/3+
Voltage Rating (20 amp dedicated circuit required) 115V (20 amp dedicated circuit required); 230V (subject to availability) 115V (20 amp dedicated circuit required); 230V (subject to availability) 115V (20 amp dedicated circuit required); 230V (subject to availability)
Weight (lbs) 115 115 115
Amps 9 (running amps) 9 (running amps) 9 (running amps)
Duct Size 8″ supply • 10″ return (evaporator and condenser)
Drainline 1/2” ID clear plastic tubing (10 feet provided)
Installation Can be installed up to 25 duct feet away from cellar.
Thermostat Advanced digital display (50ft. cable), liquid-temperature-measuring bottle probe (50ft. cable)
Temp. Delta Can maintain a 55°F cellar temperature with up to 110°F condenser air intake temperature

MAGNUM FULLY DUCTED SPLIT SERIES

  • New sleek black metal kit with a durable finish
  • Flare fittings allow quick, brazing-free installation
  • KDT digital controller/thermostat with 50-ft. cable
  • 3-speed fan switch for precise airflow management
  • Built to perform in ambient temperatures as low as -20°F
  • Stainless steel drip tray for durability and easy maintenance
  • Quiet, efficient operation for a peaceful cellar environment
  • Fully ducted split system designed for large-scale wine cellars
  • 220V High-Efficiency (H.E.) condenser for powerful performance
  • Interchangeable evaporator airflow panels for installation flexibility
  • Liquid-temperature-measuring bottle probe for precise control

Optional Accessories

  • UV-C Lighting System
  • 24V Thermostat Conversion Kit

California Residents: PROPOSITION 65 WARNING

OWNER MANUALS

CHARGE CHARTS

PRODUCT SHEETS

220V H.E. Product Sheet

Download Product Sheet

220V (Copeland) Product Sheet

Download Product Sheet

QUICK START GUIDES

Part Number
S-CCMS9000
S-CCMS12000
Cellar Size 3000 4000
BTUh (w/85°F air entering the condenser coil) Sensible/Total 10145 / 10786 11704 / 13844
CFM Evaporator: 810
Dimensions Evaporator: 29.5”L x 30.9”W x 19.8”H • Condenser: 31.18″L x 10.75″W x 21.18″H
Refrigerant R-134a
HP 3/4 1 1/4
Voltage Rating Evaporator: 120V (15-amp dedicated circuit required)
Condenser: 220V (15 amp dedicated circuit required)
Evaporator: 120V (15-amp dedicated circuit required)
Condenser: 220V (20 amp dedicated circuit required)
Weight (lbs) Evaporator: 96 • Condenser: 64 Evaporator: 96 • Condenser: 84
Amps Evaporator: 9.2 (Running Amps)
Condenser: LRA 20, RLA 4.25, FLA 4.89
Evaporator: 3.2 (running amps)
Condenser: LRA 23.6, RLA 5.76, FLA 6.6
Line Set Liquid line 3/8” OD; Suction line 5/8” OD (lessthan 50 ft.), 3/4” (greater than 50 ft.) Liquid line 3/8” OD; Suction line 5/8” OD (lessthan 50 ft.), 3/4” (greater than 50 ft.)
Drainline 3/4” ID CPVC
Installation Evaporator unit can be installed up to 25 duct feet away from the cellar. Condensing unit can be installed up to 100 feet.
Thermostat Advanced digital display (50-ft. cable), liquid-temperature-measuring bottle probe (50-ft. cable)
Temp. Delta Evap can maintain a 55°F cellar temperature with up to 120°F condenser air intake temperature. Cond can maintain a 55°F cellar temperature with up to 120°F condenser air intake temperature. 
24v Thermostat Conversion Kit Thermostat Conversion Kit that allows you to connect your cooling unit to any after market 24v thermostat. (Optional)

MAGNUM FULLY DUCTED TWIN SPLIT SERIES

  • New sleek black metal kit with a durable finish
  • Flare fittings allow quick, brazing-free installation
  • KDT digital controller/thermostat with 50-ft. cable
  • 3-speed fan switch for precise airflow management
  • Built to perform in ambient temperatures as low as -20°F
  • Stainless steel drip tray for durability and easy maintenance
  • Quiet, efficient operation for a peaceful cellar environment
  • Fully ducted split system designed for large-scale wine cellars
  • 220V High-Efficiency (H.E.) condenser for powerful performance
  • Interchangeable evaporator airflow panels for installation flexibility
  • Liquid-temperature-measuring bottle probe for precise control

Optional Accessories

  • Twin UV-C Lighting System 
  • 24V Thermostat Conversion Kit

California Residents: PROPOSITION 65 WARNING

OWNER MANUALS

220V H.E. Owner Manuals

Download Tech Manual
Download Twin Owner Manual

For previous model owner manuals, please contact us.

CHARGE CHARTS

PRODUCT SHEETS

220V H.E. Product Sheet

Download Product Sheet

QUICK START GUIDES

EVAPORATOR
Part Number S-CCMS18000 S-CCMS24000
Cellar Size 5000 cu. ft.* 7500 cu. ft.*
BTU/h (60°F condenser air
intake
15513 / 18250 22893 / 26933
BTU/h (75°F condenser air
intake
14582 / 17155 21977 / 25856
BTU/h (85°F condenser air
intake
13806 / 16243 21519 / 25317
dBA 58 58
Dimensions 29.5”L x 30.9”W x 19.8”H
Refrigerant R-134a
Voltage Rating 120V (15-amp dedicated circuit required)
Weight (lbs) 96
Amps 9.2 (Running Amps)
Drain Line 3/4” ID CPVC
Installation Evaporator unit can be installed up to 25 duct feet away from the cellar.
Thermostat Advanced digital display (50-ft. cable), liquid-temperature-measuring bottle probe (50-ft. cable)
Temp. Delta Can maintain a 55°F cellar temperature with up to 120°F condenser air intake temperature
Warranty Two-year limited warranty (parts and labor)
CONDENSER
Model 18000 24000
dBA 52 58
Dimensions 31.18″L x 10.75″W x 23.25″H 35.25″L x 12″W x 33.7″H
Condensing Unit HP 2HP 3HP
Voltage Rating 220V (15-amp dedicated circuit required) 220V (25-amp dedicated circuit required)
Weight (lbs) 116 171
Amps LRA 37, RLA 6.5, FLA 7.56 LRA 46.6, RLA 11.39, FLA 13
Line Set Liquid line 3/8” OD; Suction line 5/8” OD (less than 50 ft.), 3/4” (greater than 50 ft.)
Installation Condensing unit can be installed up to 100 line feet from evaporator unit.
Temp. Delta Can maintain a 55°F cellar temperature with up to 120°F condenser air intake temperature.
Warranty Two-year limited warranty (parts and labor)

CEILING MOUNT (CM) SPLIT SERIES

  • Virtually invisible inside the cellar
  • Built-in condensate pump system
  • Efficient airflow circulation for consistent cooling
  • Flare fittings allow quick, brazing-free installation
  • KDT digital controller/thermostat with 50-ft. cable
  • 2-speed fan switch for precise airflow management
  • Easy-access design with all connections at the base
  • Available with either 110V or 220V condenser options
  • Built to perform in ambient temperatures as low as -20°F
  • Liquid-temperature-measuring bottle probe for precise control
  • E-coated evaporator coil for improved performance and extended system life
  • Hex mesh grille with built-in air filter to guard against harmful debris

Optional Accessories

  • Omni Condenser Ducting Kit 
  • 24V Thermostat Conversion Kit
  • Omni Exterior Condenser Housing

California Residents: PROPOSITION 65 WARNING

Part Number
S-CCCM2500-220-4
S-CCCM-OMNI2500
S-CCCM3500-220
S-CCCM-OMNI3500
S-CCCM5000-220
S-CCCM-OMNI5000
Cellar Size 500 1000 2000
BTUh (w/85°F air entering the condenser coil) Sensible / Total 2188/2640 4945 / 5351 5157 / 5544
CFM 107 321 321
Dimensions Evaporator: 25.05” L x 11.34” W x 11.17” H
Condenser: 31.18″L x 10.75″W x 21.18″H
Evaporator: 35.75”L x 14.5”W x 12.75”H
Condenser: 31.18″L x 10.75″W x 21.18″H
Refrigerant R-134a R-134a R-134a
HP 0.35HP 0.6HP 0.7HP
Voltage Rating (15 amp dedicated circuit required) 120V (15-amp dedicated circuit required), 220V (15-amp dedicated circuit required) 120V (15-amp dedicated circuit required), 220V (15-amp dedicated circuit required) 120V (15-amp dedicated circuit required), 220V (15-amp dedicated circuit required)
Weight (lbs) Evaporator:50 • Condenser:50 Evaporator:90 • Condenser:60
Amps Evaporator: 1 (running amps)
Condenser: LRA 26/RLA 4.4
Evaporator: 1 (running amps)
Condenser: LRA 43/RLA 8
dBA (Evaporator) 35 Evap /48 Cond  48 Evap /45 Cond  53 Evap /48 Cond
Line Set Liquid line 1/4” OD; Suction line 3/8” OD (lessthan 50 ft.), 1/2” (greater than 50 ft.) Liquid line 1/4” OD; Suction line 1/2” OD (lessthan 50 ft.), 5/8” (greater than 50 ft.)
Drainline 1/4″ ID clear plastic tubing (not provided)- Rigid tube recommended 1/4″ ID clear plastic tubing (not provided)- Rigid tube recommended
Installation Evaporator is installed in the cellar. Condensing unit can be installed up to 100 line feet from evaporator unit.
Thermostat Advanced digital display (50-ft. cable), liquid-temperature-measuring bottle probe (50-ft. cable)
Temp. Delta Can maintain a 55°F cellar temperature with up to 120°F condenser air intake temperature
24v Thermostat Conversion Kit Advanced digital display (50-ft. cable), liquid-temperature-measuring bottle probe (50-ft. cable), 24V – customer supplied

CEILING MOUNT (CM) TWIN SPLIT SERIES

  • Virtually invisible inside the cellar
  • Built-in condensate pump system
  • Efficient airflow circulation for consistent cooling
  • Flare fittings allow quick, brazing-free installation
  • KDT digital controller/thermostat with 50-ft. cable
  • 2-speed fan switch for precise airflow management
  • Easy-access design with all connections at the base
  • Built to perform in ambient temperatures as low as -20°F
  • Liquid-temperature-measuring bottle probe for precise control
  • 220V High-Efficiency (H.E.) condenser for powerful performance
  • E-coated evaporator coil for improved performance and extended system life
  • Hex mesh grille with built-in air filter to guard against harmful debris

Optional Accessories

  • 24V Thermostat Conversion Kit
  • Large Exterior Condenser Housing

California Residents: PROPOSITION 65 WARNING

OWNER MANUALS

220V H.E. Owner Manuals

Download Twin Owner Manual

220V Copeland Owner Manuals

Download Addendum Manual
Download Twin Owner Manual
Download (24V) Twin Owner Manual

For previous model owner manuals, please contact us.

CHARGE CHARTS

220V H.E. Charge Charts

Download Twin CHARGE CHART

PRODUCT SHEETS

220V H.E. Product Sheet

Download Product Sheet

QUICK START GUIDES

220V H.E. Quick Start Guides

Download TWIN QUICK START GUIDE
Part Number
S-CCCM9000-220

S-WKCM9000-000-CW3

S-CCCM12000-220
Cellar Size 3000 3500
BTUh (w/85°F air entering the condenser coil) Sensible/Total 8631 / 9183 10268 / 11306
CFM Evaporator: 810
Dimensions Evaporator: 35.75”L x 14.5”W x 12.75”H • Condenser: 31.18″L x 10.75″W x 23.25″H
Refrigerant R-134a
HP 1HP 1.5HP
Voltage Rating Evaporator: 120V (15-amp dedicated circuit required)
Condenser: 220V (15 amp dedicated circuit required)
Evaporator: 120V (15-amp dedicated circuit required)
Condenser: 220V (20 amp dedicated circuit required)
Weight (lbs) Evaporator: 53 • Condenser: 48 Evaporator: 53 • Condenser: 52
Amps Evaporator: Primary 1.74 (Running Amps); Secondary 1.04 (Running Amps)
Condenser: LRA 20, RLA 4.25, FLA 4.89
Evaporator: Primary 1.74 (Running Amps); Secondary 1.04 (Running Amps)
Condenser: LRA 23.6, RLA 5.76, FLA 6.6
Line Set Liquid line 3/8” OD; Suction line 5/8” OD (lessthan 50 ft.), 3/4” (greater than 50 ft.) Liquid line 3/8” OD; Suction line 5/8” OD (lessthan 50 ft.), 3/4” (greater than 50 ft.)
Drainline 3/4” ID CPVC
Installation Evaporator unit can be installed up to 25 duct feet away from the cellar. Condensing unit can be installed up to 100 feet.
Thermostat Advanced digital display (50-ft. cable), liquid-temperature-measuring bottle probe (50-ft. cable)
Temp. Delta Evap can maintain a 55°F cellar temperature with up to 120°F condenser air intake temperature. Cond can maintain a 55°F cellar temperature with up to 120°F condenser air intake temperature. 
24v Thermostat Conversion Kit Thermostat Conversion Kit that allows you to connect your cooling unit to any after-market 24v thermostat. (Optional)

WALL MOUNT (WM) SPLIT SERIES

  • Designed for small to medium-scale wine cellars
  • Efficient airflow circulation for consistent cooling
  • Flare fittings allow quick, brazing-free installation
  • KDT digital controller/thermostat with 50-ft. Cable
  • Available with either 110V or 220V condenser options
  • Built to perform in ambient temperatures as low as -20°F
  • Wall-mounted evaporator eliminating the need for ducting
  • Liquid-temperature-measuring bottle probe for precision control
  • E-coated evaporator coil for improved performance and extended system life

Optional Accessories

  • UV-C Lighting System
  • Omni Condenser Ducting Kit
  • 24V Thermostat Conversion Kit
  • Omni Exterior Condenser Housin

California Residents: PROPOSITION 65 WARNING

Part Number
S-CCWM2500-220-2
S-CCWM-OMNI2500
S-CCWM3500-220
S-CCWM-OMNI3500
S-CCWM5000-220-3
S-CCWM-OMNI5000
Cellar Size 500 1000 1750
BTUh (w/85°F air entering the condenser coil) 2078 / 2492 4244 / 4453 4577 / 4982
CFM 94 270
Dimensions Evaporator: 13”L x 20”W x 10.5”H
Condenser: 31.18″L x 10.75″W x 21.18″H
Evaporator: 16.1”L x 20.5”W x 15.5”H
Condenser: 31.18″L x 10.75″W x 21.18″H
Refrigerant R-134a R-134a R-134a
HP 0.35HP 0.6HP 0.7HP
Voltage Rating Evaporator: 115V (15 amp dedicated circuit required)
Condenser: 220V (15-amp dedicated circuit required)
Evaporator: 115V (15 amp dedicated circuit required)
Condenser: 220V (15-amp dedicated circuit required)
Weight (lbs) Evaporator: 50 • Condenser: 50 Evaporator: 60 • Condenser: 60 Evaporator: 60 • Condenser: 60
Amps Evaporator: 0.97 (Running Amps)
Condenser: LRA 5.3A, RLA 1.55A, FLA 1.7A
Evaporator: 2.2 (Running Amps), Compressor:LRA 10.7, RLA 2.7, FLA 3.1 Evaporator: 2.2 (Running Amps)
Compressor: LRA 13.2, RLA 3.19, FLA 3.66
dBA (Evaporator) 51/65 55/65 56/65
Line Set Liquid line 1/4” OD; Suction line 3/8” OD (lessthan 50 ft.), 1/2” (greater than 50 ft.) Liquid line 1/4” OD; Suction line 1/2” OD (lessthan 50 ft.), 5/8” (greater than 50 ft.) Liquid line 1/4” OD; Suction line 1/2” OD (lessthan 50 ft.), 5/8” (greater than 50 ft.)
Drainline 1/2″ ID clear plastic tubing (not provided)
Installation Evaporator is installed in the cellar. Condensing unit can be installed up to 100 line feet from evaporator unit.
Thermostat Advanced digital display (50-ft. cable), liquid-temperature-measuring bottle probe (50-ft. cable)
Temp. Delta Can maintain a 55°F cellar temperature with up to 120°F condenser air intake temperature
24v Thermostat Conversion Kit Thermostat Conversion Kit that allows you to connect your cooling unit to any after-market 24v thermostat. (Optional)

WALL MOUNT (WM) TWIN SPLIT

  • Designed for medium to large-scale wine cellars
  • Efficient airflow circulation for consistent cooling
  • Flare fittings allow quick, brazing-free installation
  • KDT digital controller/thermostat with 50-ft. Cable
  • Built to perform in ambient temperatures as low as -20°F
  • Wall-mounted evaporators eliminating the need for ducting
  • 220V High-Efficiency (H.E.) condenser for powerful performance
  • Liquid-temperature-measuring bottle probe for precision control
  • E-coated evaporator coil for improved performance and extended system life

Optional Accessories

  • Twin UV-C Lighting System 
  • 24V Thermostat Conversion Kit
  • Large Exterior Condenser Housing

California Residents: PROPOSITION 65 WARNING

OWNER MANUALS

220V H.E. Owner Manuals

Download Twin Owner Manual

220V Copeland Owner Manuals

Download Twin Owner Manual

For previous model owner manuals, please contact us.

CHARGE CHARTS

220V H.E. Charge Charts

Download Twin CHARGE CHART

PRODUCT SHEETS

220V H.E. Product Sheet

Download Product Sheet

QUICK START GUIDES

220V H.E. Quick Start Guides

Download TWIN QUICK START GUIDE
Part Number
S-CCWM9000-115-5
S-CCWM9000-220
WM9000-24V
Cellar Size Approx. 3000 (Each wine cellar is unique and has specific cooling requirements. Heat load calculations should always be performed prior to selecting a cooling unit.)
BTUh (w/85°F air entering the condenser coil) 7779 / 8054
CFM 200 (per unit)
Dimensions Evaporator: 16.1″L x 20.5″W x 15.5″H (x2) • Condensing Unit: 31.18″L x 10.75″W x 21.18″H
Refrigerant R-134a
Voltage Rating Evaporator: 115V (15 amp dedicated circuit required) Condenser: 220V (15-amp dedicated circuit required)
Weight (lbs) Evaporators: 54 (per unit) • Condensing Unit: 64
Amps Evaporator: Primary 2.48 (Running Amps) ; Secondary (2.2 Running Amps), Compressor: LRA 20, RLA 4.25, FLA 4.89
Line Set Liquid Line 3/8″OD; Suction Line 5/8″OD (lessthan 50 ft.), 3/4″ (greater than 50 ft.)
Drainline 1/2” ID clear plastic tubing (not included)
Installation Evaporator is installed in the cellar. Condensing unit can be installed up to 100 line feet from evaporator unit.
Thermostat Advanced digital display (50-ft. cable), liquid-temperature-measuring bottle probe (50-ft. cable)
Temp. Delta Can maintain a 55°F cellar temperature with up to 120°F condenser air intake temperature
24v Thermostat Conversion Kit Thermostat Conversion Kit that allows you to connect your cooling unit to any after-market 24v thermostat. (Optional)

FULLY DUCTED (FD) SPLIT SERIES

  • Designed for small to medium-scale wine cellars
  • Flare fittings allow quick, brazing-free installation
  • KDT digital controller/thermostat with 50-ft. Cable
  • Available with either 110V or 220V condenser options
  • Built to perform in ambient temperatures as low as -20°F
  • Fully ducted split system designed for quiet, efficient operation
  • Liquid-temperature-measuring bottle probe for precision control
  • E-coated evaporator coil for improved performance and extended system life

Optional Accessories

  • UV-C Lighting System
  • Omni Condenser Ducting Kit
  • 24V Thermostat Conversion Kit
  • Omni Exterior Condenser Housing

The Fully Ducted coils are mounted outside the cellar so all that is seen inside the cellar is the air supply and return grills.

California Residents: PROPOSITION 65 WARNING

OWNER MANUALS

220V H.E. Owner Manuals

Download Owner Manual

110V OMNI Owner Manuals

Download Owner Manual

110V/220V Copeland Owner Manuals

Download Owner Manual

For previous model owner manuals, please contact us.

CHARGE CHARTS

220V H.E. Charge Charts

Download 3500/5000 CHARGE CHART

110V Omni Charge Charts

Download 3500/5000 CHARGE CHART

PRODUCT SHEETS

220V H.E. Product Sheet

Download Product Sheet

110V OMNI Product Sheet

Download Product Sheet

110V/220V Copeland Product Sheet

Download Product Sheet

QUICK START GUIDES

220V H.E. Quick Start Guides

Download 3500/5000 QUICK START GUIDE

110V Omni Quick Start Guides

Download 3500/5000 QUICK START GUIDE
Part Number
S-CCFD3500-220
S-CCFD-OMNI3500
S-CCFD5000-220-3
S-CCFD-OMNI5000
Cellar Size 1000 1750
BTUh (w/85°F air entering the condenser coil) 4082 / 4277 4479 / 4879
CFM 200 200
Dimensions Evaporator: 16.1″L x 20.5″W x 15.5″H • Condenser: 31.18″L x 10.75″W x 21.18″H
Refrigerant R-134a R-134a
HP 0.6HP 0.7HP
Voltage Rating Evaporator: 115V (15 amp dedicated circuit required)
Condenser: 220V (15-amp dedicated circuit required)
Evaporator: 115V (15 amp dedicated circuit required)
Condenser: 220V (15-amp dedicated circuit required)
Weight (lbs) Evaporator: 56 • Condenser: 55 Evaporator: 56 • Condenser: 56
Amps Evaporator: 2.2 (running amps) • Condenser: LRA 10.7, RLA 2.7, FLA 3.1 Evaporator: 2.2 (running amps) • Condenser: LRA 13.2, RLA 3.19, FLA 3.66
dBA (Evaporator/Condenser) 42 / 45 42 / 48
Ducting 8″ Supply • 10″ Return
Line Set Liquid line 1/4” OD; Suction line 1/2” OD (lessthan 50 ft.), 5/8” (greater than 50 ft.)
Drainline 1/2″ ID clear plastic tubing (not provided)
Installation Evaporator can be installed up to 25 duct feet away from cellar. Condensing unit can be installed up to 100 line feet from evaporator unit.
Thermostat Advanced digital display (50-ft. cable), liquid-temperature-measuring bottle probe (50-ft. cable)
Temp. Delta Can maintain a 55°F cellar temperature with up to 120°F condenser air intake temperature
24v Thermostat Conversion Kit Thermostat Conversion Kit that allows you to connect your cooling unit to any after market 24v thermostat. (Optional)

FULLY DUCTED (FD) TWIN SPLIT SERIES

  • Designed for medium to large-scale wine cellars
  • Flare fittings allow quick, brazing-free installation
  • KDT digital controller/thermostat with 50-ft. Cable
  • Built to perform in ambient temperatures as low as -20°F
  • Fully ducted split system designed for quiet, efficient operation
  • 220V High-Efficiency (H.E.) condenser for powerful performance
  • Liquid-temperature-measuring bottle probe for precision control
  • E-coated evaporator coil for improved performance and extended system life

Optional Accessories

  • Twin UV-C Lighting System
  • 24V Thermostat Conversion Kit
  • Large Exterior Condenser Housing

California Residents: PROPOSITION 65 WARNING

OWNER MANUALS

220V H.E. Owner Manuals

Download Twin Owner Manual

220V Copeland Owner Manuals

Download Twin Owner Manual

For previous model owner manuals, please contact us.

CHARGE CHARTS

220V H.E. Charge Charts

Download Twin CHARGE CHART

PRODUCT SHEETS

220V H.E. Product Sheet

Download Product Sheet

110V/220V Copeland Product Sheet

Download Product Sheet

QUICK START GUIDES

220V H.E. Quick Start Guides

Download TWIN QUICK START GUIDE
Part Number
S-CCFD9000-115-5
S-CCFD9000-220
FD9000-24V
Cellar Size Approx. 3000 (Each wine cellar is unique and has specific cooling requirements. Heat load calculations should always be performed prior to selecting a cooling unit.)
BTUh (w/85°F air entering the condenser coil) 7281 / 7879
CFM 200 (per unit)
Dimensions Evaporator: 16.1″L x 20.5″W x 15.5″H (x2) • Condenser: 31.18″L x 10.75″W x 21.18″H
Refrigerant R-134a
Voltage Rating Evaporator: 115V (15 amp dedicated circuit required) Condenser: 220V (15 amp dedicated circuit required)
Weight (lbs) Evaporators: 56 (per unit) • Condensing Unit: 64
Amps Evaporator: Primary 2.48 (Running Amps) ; Secondary (2.2 Running Amps) • Condenser: LRA 50/RLA 9.3
Duct Size 8″ Supply (x2) • 10″ Return (x2)
Drainline 1/2″ ID clear plastic tubing (not included)
Installation Evaporator can be installed installed up to 25 duct feet away from cellar. Condensing unit can be installed up to 100 line feet from evaporator unit.
Thermostat Advanced digital display (50-ft. cable), liquid-temperature-measuring bottle probe (50-ft. cable)
Temp. Delta Can maintain a 55°F cellar temperature with up to 120°F condenser air intake temperature
24v Thermostat Conversion Kit Thermostat Conversion Kit that allows you to connect your cooling unit to any after market 24v thermostat. (Optional)

24V THERMOSTAT CONVERSION KIT

  • Plug-and-play design allows fast, simple installation
  • Track runtimes and energy usage for improved efficiency
  • Monitor cellar temperature remotely from any mobile device
  • Now offered as an aftermarket upgrade, not just at purchase
  • Converts standard controller to a 24V thermostat of your choice
  • Set custom alerts for temperature changes and system performance
  • Compatible with Nest, Ecobee, Honeywell, and other smart thermostats

*24-volt thermostats not included with purchase of 24-volt thermostat conversion kit.

*24-volt thermostat must be placed inside wine cellar, preferably in a central location away from direct airflow.

UV-C LIGHTING SYSTEM

  • Prevents mold growth within the system
  • Reduces air-borne pathogens and allergen levels
  • Reduces unpleasant smells within the cellar
  • Maintains an overall healthier cellar environment.
  • Available on Ultimate PLus, Optimum, & Fully-Ducted/Wall-Mount Systems

Ultraviolet Germicidal Irradiation (UVGI) is a disinfection method that uses short-wavelength ultraviolet (UV-C) light to kill microorganisms such as fungus, mold, mildew, and bacteria. The application of UV-C light to disinfect has been an accepted practice since the 1950s and is used in a variety of applications such as food, air, and water purification.

OPTIMUM DUCT KITS

  • Integrated heat sensor for safe, efficient operation
  • Simple installation with all necessary components included
  • Relocates unwanted heat from the exhaust side of Optimum units
  • Improves cellar environment by venting heat to an alternate location
  • Includes duct plenum, transitions, in-line fan, and adjustable elbow for complete setup

Small Ducting Kit

  • Compatible with Optimum 2200, 3300, 4400

Large Ducting Kit

  • Compatible with Optimum 8800

OPTIMUM EXTERIOR GRILLE

  • Sleek, low-profile design for a clean exterior finish
  • Ensures long-term durability and system protection
  • Shields exhaust side of unit from outdoor weather elements
  • Compatible with Optimum 2200, 3300, 4400, and 8800 models

ULTIMATE EXTERIOR GRILLE  

  • Designed for seamless fit with Ultimate Series units
  • Durable construction for long-lasting exterior protection
  • Compatible with ducted Ultimate 3300, 4400, and 8800 models
  • Improves reliability and performance in exterior wall installations
  • Shields the exhaust side of the system from outdoor weather elements

ULTIMATE DUCT PLENUMS

  • Durable construction ensures long-term performance
  • Compatible with Ultimate 3300, 4400, and 8800 models
  • Expands installation options for tighter or unique spaces
  • Direct cold air into the cellar or vent hot exhaust air outside
  • Allows ducting on either side of the unit for maximum flexibility

ULTIMATE FILTERS

  • Help extend the life of your cooling unit
  • Improve air quality and system efficiency
  • Recommended replacement every 3 months
  • Easy-to-install replacement filters for Ultimate systems
  • Compatible with ducted Ultimate 3300, 4400, and 8800 models
  • 3300/4400 Dimensions: 11 ¾” x 9″ x 1″
  • 8800 Dimensions: 11 ¾” x 13 ½” x 1″

CONDENSATE PUMP

  • ½-gallon leakproof, rustproof ABS tank
  • Stainless steel shaft with snap-action switch
  • Quick, easy installation with compact design
  • Pumps excess condensate up to 20 ft. away
  • Fully automatic operation with 3 drain holes
  • Thermal overload protection for motor safety
  • Suitable for high-efficiency and gas-furnace condensate
  • ABS tank cover and polypropylene impeller for durability
  • Removable ⅜″ barbed check valve for easy maintenance

BTU Wizard

Size Your Cooling System

START BTU WIZARD

Sales Rep Locator

Locate A CellarCool Dealer

LOCATE A SALES REP

Have Any Questions?

Feel Free To Contact Our Team!

CONTACT US